Vent control
Auto-PEEP / dynamic hyperinflation
Start with the expiratory flow-time scalar, then assess hemodynamics and measure total PEEP only when the maneuver is valid.
HAMILTON-T1 AutoPEEPFlow waveform plus the calculated monitored value.Recognize the patternExpiratory flow or volume fails to return to baseline.Check hemodynamicsDynamic hyperinflation can reduce venous return and cause shock.Total PEEP / AutoPEEP methodTechnique depends on the ventilator; HAMILTON-T1 uses a calculated monitored value.Increase expiratory timeLower RR, shorten Ti/increase flow, and reduce VT if appropriate.Treat obstructive physiologyAsthma/COPD/bronchospasm pathway.
Evidence and use limits
Last reviewed: 2026-07-17. Designed for: emergency medicine learners, clinicians, EMS, RT, and airway educators.
For clinician education and reference. Apply clinical judgment and local protocols.
Full references · Editorial policy · AARC 2024 ventilator assessment · ATS/ESICM/SCCM lung-protective ventilation · ATS 2024 ARDS update